Main Category:
                                    
                                        MEASUREMENT AND TEST INSTRUMENTATION
                                    
                                    
                                    Secondary Category:
                                    
                                        ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
                                    
                                    
                                    
                                        Specification
                                        
                                            Campo Elettrico: Sė
                                        
                                        
                                            Campo Magnetico: Sė
                                        
                                        
                                            Campo Elettromagnetico: Sė
                                        
                                        
                                        
                                            Status:
                                            
                                                AVAILABLE
                                            
                                            
                                            Brand:
                                            
                                                NARDA PMM
                                            
                                            
                                            Model Name:
                                            
                                                AMB-8057-02
                                            
                                            
                                            
                                                    
                                                    
                                                        Item Code:
                                                        
                                                            NARDA PMM AMB-8057-02 DB
                                                        
                                                        
                                                            
                                                            Applications:
                                                            
                                                                
                                                                                                                            Measures Work Environments EMF
                                                                                                                            
                                                                                                                                            Environmental measures EMF LF
                                                                                                                                            
                                                                                                                                                    Environmental measures EMF RF
                                                                                                                                                    
                                                            
                                                            
                                                            
                                                            Description:
                                                            
                                                                Continuous monitoring station by a large band of electric fields, magnetic and electromagnetic fields from 10 Hz to 7 GHz (depending on the probe) without solar panel with long life lithium battery supply
								
                                                            
                                                            
                                                            
                                                                General Features:
                                                                
                                                                    Available in various field probes as needed. Direct sensor input connector standard Narda
                                                                            Multiple 8057 units (can be connected to the base station via the GSM network) can be used to build reliable control systems and to cover large geographical areas, including national coverage.
                                                                                    Automatic discharge and manual data entry on the PC base station via the GSM modem internal acquisition software dedicated to data collection and analysis.
                                                                                            Internal rechargeable by solar panel
                                                                                                    Dual band GSM module with SIM card holder entitled to receive and transmit data to and from landline and mobile
                                                                                                            RS 232 or landline modem. Output parallel service for internal diagnostics.
                                                                                                                    Security Alarms: microswitch tamper switch, internal over-temperature, low battery, sondaguasta.
                                                                                                                            Dimensions: 60 x 780 (diameter x height) mm
                                                                                                                                    Weight: 2.4 Kg
                                                                                                                                            Replaceable lithium battery 3.6 V, 13 A / h
                                                                                                                                                    
                                                                
                                                                
                                                                    
                                                                    
                                                                        Specifications:
                                                                        
                                                                            Running time: approximately 8 months with a daily transmission of 1min. (Autonomy depends on the probe in use and settings)
                                                                                    IP54
                                                                                            Automatic Generation of TXT file on each dowload made
                                                                                                    SMS: up to two phones
                                                                                                            Automatic self-test during power up and every 7 days or remotely.
                                                                                                                    Operating temperature: -10 to + 50 ° C
                                                                                                                            Dynamic depending on the probe used
                                                                                                                                    Scope of work: Electric from 0.02 V / m - 200 V / m from 50 nT Magnetic - 200 mT
                                                                                                                                            Resolution: Electric 0.01 V / m; 1 nT magnetic
                                                                                                                                                    Sensitivity-dependent probe
                                                                                                                                                            Accuracy: Probe dependent
                                                                                                                                                                    Unit of measurement: V / m; nT; mT
                                                                                                                                                                            Measuring range: X, Y, Z and total Max, AVG, RMS
                                                                                                                                                                                    Sampling: X, Y, Z every 3 sec
                                                                                                                                                                                            Interval: 30 sec, 15 min
                                                                                                                                                                                                    Maximum time of acquisition: With probe 1 and 3-band: 338 days with 15 min retention interval, 11 days with 30 sec interval memorizzazzione. Probe 4-band: 169 days with 15 min retention interval, 5 days with 30 sec interval memorizzazzione
                                                                                                                                                                                                            Data Download: manual, automatic control unit operated by a set time, automatic PC
                                                                                                                                                                                                                    Functions: AVG, RMS, peak, recording temperature and battery voltage
                                                                                                                                                                                                                            Alarms: Two programmable thresholds (threshold of concern and alarm) and automatic alert of overcoming them that their return to their limits.
                                                                                                                                                                                                                                    
                                                                        
                                                                        
                                                                            
                                                                            
                                                                                Associated Courses:
                                                                                
                                                                                    RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
                                                                                            FUNDAMENTALS OF RADIO PROPAGATION AND ANTENNAS
                                                                                                                                                        UNCERTAINTIES IN MEASURING EQUIPMENT