mpb assistenza e faq mpb video

» MEASUREMENT AND TEST INSTRUMENTATION » ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS » 8055

  

GET YOUR QUOTE

Main Category:

MEASUREMENT AND TEST INSTRUMENTATION

Secondary Category:

ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS

Specification

Campo Elettrico: Sì

Campo Magnetico: Sì

Campo Elettromagnetico: Sì

Status:

AVAILABLE

Brand:

NARDA PMM

Model Name:

8055

Item Code:

NARDA PMM 8055 DB

Applications:

Measures Work Environments EMF
Environmental measures EMF LF
Environmental measures EMF RF

Description:

Continuous monitoring station by a large band of electric fields, magnetic and electromagnetic fields from 10 Hz to 40 GHz (depending on the probe) with 2 solar panels

General Features:

Available in various field probes as needed. Direct sensor input connector standard Narda
Multiple 8055 units (can be connected to the base station via the GSM network) can be used to build reliable control systems and to cover large geographical areas, including national coverage.
Automatic discharge and manual data entry on the PC base station via the GSM modem internal acquisition software dedicated to data collection and analysis.
Solar panels and rechargeable battery, for an unlimited number of outdoor operations.
Dual band GSM module with SIM card holder entitled to receive and transmit data to and from mobile and telefoniafissa
RS 232 or landline modem. Output parallel service for internal diagnostics.
Security Alarms: microswitch tamper switch, internal over-temperature, low battery, sondaguasta.
Dimensions: 200 X 200 X 710 mm
Weight: 5 Kg
Internal Battery: Lead Acid 6V, 2.8 A / h

Specifications:

Power consumption: 10 mA GSM off, 30 mA GSM standby, 350 mA GSM transmission.
External Power: DC 10-15 V, 200 mA
Running time: 7 days in total darkness by a drive of 10 minutes per day.
Charging time: less than 24 hours with external power supply.
Automatic self-test during power up and every 7 days or remotely.
Operating temperature: -10 to + 40 ° C
Dynamic depending on the probe used
Scope of work: Electric from 0.03 V / m - 100 kV / m from 10 nT Magnetic - 10 mT
Resolution: Electric from 0.01 to 100 V / m, from 0.1 nT Magnetic - 0.1 mT
Sensitivity-dependent probe
Accuracy: Probe dependent
Unit of measurement: V / m kV / m; uW / cm 2, mW / cm 2, W / m 2, A / m, nT, UT; mT.
Measuring range: X, Y, Z and total max average.
Sampling: 1 measurement / sec
Interval: 5,10,15,30 sec; 1,2,6 min
Memory: 256 Kbytes
Maximum time of acquisition: 18 months with 1 sample every 6 min.
Data Download: manual, automatic control unit operated by a set time, automatic PC
Functions: AVG, RMS, peak, daily report via SMS.
Alarms: Two programmable thresholds (threshold of concern and alarm) and automatic alert of overcoming them that their return to their limits. Send SMS up to 10 phones.

Associated Courses:

RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
FUNDAMENTALS OF RADIO PROPAGATION AND ANTENNAS
UNCERTAINTIES IN MEASURING EQUIPMENT

MORE INFORMATION

Related Articles: 13

mpb EP-33-A.jpg

NARDA PMM EP-33-A DB

HIGH FREQUENCY

Isotropic-band GSM selective sensor for measuring the electrical component of the electromagnetic field in the range from 925 to 960 MHz

mpb EP-745.jpg

NARDA PMM EP-745 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 7 GHz

mpb EP-645.jpg

NARDA PMM EP-645 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 6.5 GHz

mpb EP-330.jpg

NARDA PMM EP-330 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 3 GHz

mpb EP-333.jpg

NARDA PMM HP-032 DB

HIGH FREQUENCY

Probe for measuring the magnetic component of the electromagnetic field in the frequency range 100 kHz - 30 MHz

mpb HP-102.jpg

NARDA PMM HP-102 DB

HIGH FREQUENCY

Probe for measuring the magnetic component of the electromagnetic field in the frequency range 30 MHz - 1 GHz

mpb EP-408.jpg

NARDA PMM EP-408 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 1 MHz - 40 GHz

mpb EP-183.jpg

NARDA PMM EP-183 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 1 MHz-18 GHz

mpb EP-300.jpg

NARDA PMM EP-300 DB

HIGH FREQUENCY

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 3 GHz

mpb EP-33-B.jpg

NARDA PMM EP-33-B DB

HIGH FREQUENCY

Isotropic-band GSM selective sensor for measuring the electrical component of the electromagnetic field in the range 1805 - 1880 MHz

mpb HP-050.jpg

NARDA PMM HP-050 DB

LOW FREQUENCY

Probe for measuring the magnetic field in the frequency range 10 Hz - 5 kHz

mpb EP-333.jpg

NARDA PMM HP-051 DB

LOW FREQUENCY

Probe for measuring the magnetic field in the frequency range 10 Hz - 5 kHz

mpb 8055-MAST.jpg

NARDA PMM 8055-MAST DB

TRIPODS AND SUPPORTS

Base unit with handle and pole for 8055

Related Services: 2

MPB NARDA PMM 8055 STD

NARDA PMM 8055 STD

ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS

Calibration unit measuring magnetic fields and electromagnetic

MPB NARDA PMM 8055 RPR

NARDA PMM 8055 RPR

ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS

Repair control unit. 8055