Main Category:
                                        
                                            MEASUREMENT AND TEST INSTRUMENTATION
                                        
                                        
                                        Secondary Category:
                                        
                                            ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
                                        
                                        
                                        
                                            Specification
                                            
                                                Campo Elettrico: No
                                            
                                            
                                                Campo Magnetico: No
                                            
                                            
                                                Campo Elettromagnetico: Sì
                                            
                                            
                                            
                                                Status:
                                                
                                                    AVAILABLE
                                                
                                                
                                                Brand:
                                                
                                                    NARDA PMM
                                                
                                                
                                                Model Name:
                                                
                                                    8056-FLAT-6-20
                                                
                                                
                                                
                                                        
                                                        
                                                            Item Code:
                                                            
                                                                NARDA PMM 8056-FLAT-6-20 DB
                                                            
                                                            
                                                                
                                                                Applications:
                                                                
                                                                    
                                                                                                                                Measures Work Environments EMF
                                                                                                                                
                                                                                                                                                        Environmental measures EMF RF
                                                                                                                                                        
                                                                
                                                                
                                                                
                                                                Description:
                                                                
                                                                    Portable Meter EMF isotropic fixed limit be set at 6 and 20 V / m. Simultaneous measurement of the electrical component in the range 3 MHz - 40 GHz and the magnetic in the range 30 MHz - 300 MHz
								
                                                                
                                                                
                                                                
                                                                    General Features:
                                                                    
                                                                        LCD display two lines of 16 characters
                                                                                Internal battery is not rechargeable 9V PP3
                                                                                        Operating time> 2000 hours with display off, 1000 hours with LCD screen on
                                                                                                RS232 Interface Infrared (data download and firmware update)
                                                                                                        Automatic self-test during the 'power for all functions
                                                                                                                Internal calibration on the gauge EEPROM
                                                                                                                        Operating Temperature -10 to +40 ° C
                                                                                                                                Storage Temperature -20 to +70 ° C
                                                                                                                                        Dimensions (WxHxD) 62 x 30 x 190 mm
                                                                                                                                                Weight 185 g
                                                                                                                                                        
                                                                    
                                                                    
                                                                        
                                                                        
                                                                            Specifications:
                                                                            
                                                                                Electric Field:
                                                                                        Range 3 MHz - 40 GHz
                                                                                                Resolution 1% of the limit set
                                                                                                        Sensitivity 10% of the limit set
                                                                                                                Limits selectable 6 V / m 20 V / m
                                                                                                                        Measurement Units% of the limit, V / m
                                                                                                                                Scale 150% of the higher limit
                                                                                                                                        Overload 300 V / m
                                                                                                                                                Accuracy @ 20 V / m 3 MHz - 5 GHz ± 3 dB, 5 GHz - 18 GHz +6 / -4 dB, 18 GHz - 40 GHz +0 / -8 dB
                                                                                                                                                        Magnetic Field:
                                                                                                                                                                Range 30 MHz - 300 MHz
                                                                                                                                                                        Resolution 1% of the limit set
                                                                                                                                                                                Sensitivity 10% of the limit set
                                                                                                                                                                                        Limits selectable 73 mA / m or 243 mA / m
                                                                                                                                                                                                Measurement Units% of the limit, mA / m
                                                                                                                                                                                                        Scale 150% of the higher limit
                                                                                                                                                                                                                Overload 3 A / m
                                                                                                                                                                                                                        Accuracy @ 243 mA / m 30 MHz - 300 MHz ± 3 dB
                                                                                                                                                                                                                                Internal alarm buzzer is enabled when the field is: between 50% and 75% of the limit, between 75% and 100% of the limit, more than 100% of the limit
                                                                                                                                                                                                                                        Features present value and average value
                                                                                                                                                                                                                                                
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                    Associated Courses:
                                                                                    
                                                                                        RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
                                                                                                UNCERTAINTIES IN MEASURING EQUIPMENT