GET YOUR QUOTE
MEASUREMENT AND TEST INSTRUMENTATION
ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
Campo Elettrico: No
Campo Magnetico: No
Campo Elettromagnetico: Sì
AVAILABLE
NARDA PMM
AMS-8060
NARDA PMM AMS-8060 DB
                                                                    
                                                                                                                                                        Environmental measures EMF RF
                                                                                                                                                        
                                                                
Selective continuous monitoring station of electromagnetic fields from 75 to 3 GHz with Mz solar panel.
                                                                        Up to 20 different RF sources can be set for continuous monitoring
                                                                                Multiple units AMB-8060 (can be connected to the base station via the GSM network) can be used to build reliable control systems and to cover large geographical areas, including national coverage.
                                                                                        Automatic discharge and manual data entry on the PC base station via the GSM modem internal acquisition software dedicated to data collection and analysis.
                                                                                                Solar panel and internal rechargeable battery, for an unlimited number of outdoor operations.
                                                                                                        Dual band GSM module with SIM card holder entitled to receive and transmit data to and from mobile and telefoniafissa
                                                                                                                RS 232 or landline modem. Output parallel service for internal diagnostics.
                                                                                                                        Security Alarms: microswitch tamper switch, internal over-temperature, low battery, sondaguasta.
                                                                                                                                Dimensions: 260 x 740 mm Radome; Base Size 660 x 600 x 30 mm; solar panel size 500 x 600 x 51 mm Battery Size 310 x 240 x 190 mm Dimensions 760 x 60 mm support rod
                                                                                                                                        Weight: 27 Kg including battery and stand
                                                                                                                                                Internal Battery Lead 12V, 32A / h
                                                                                                                                                        
                                                                    
                                                                                Power consumption: 100 mW with a GSM handset off and off, 200 mW in standby with GSM and receiver off, and 2 W for GSM in the transmission and receiver off, 8 W with active receiver and GSM off
                                                                                        External DC supply: 100 ... 240 VAC to 24 VDC, 1.25A
                                                                                                Running time: 48 hours with active receiver.
                                                                                                        Operating temperature: -10 to + 50 ° C
                                                                                                                Frequency range: 75 MHz - 3 GHz
                                                                                                                        Dynamic range 0.01 to 300 V / m
                                                                                                                                Resolution: 0.01 V / m
                                                                                                                                        Sensitivity: 0.01 V / m (depending on the bandwidth used)
                                                                                                                                                Unit of measurement: V / m
                                                                                                                                                        Field measured: AVG, RMS, Peak
                                                                                                                                                                Sampling: <200 msec (depending on the setting of the band)
                                                                                                                                                                        Memory: 288 Kbytes
                                                                                                                                                                                Interval: 5,10,15,30 sec; 1,2,6 min (depending on the setting of the band)
                                                                                                                                                                                        Maximum time of acquisition: 50 days with sampling 6 minutes, 5 bands, no peak
                                                                                                                                                                                                Data Download: manual, automatic control unit operated by a set time, automatic PC
                                                                                                                                                                                                        Functions: AVG, RMS, peak, daily report via SMS
                                                                                                                                                                                                                GPS coordinates: latitude, longitude, GMT
                                                                                                                                                                                                                        Alarms: Exceeding threshold, open houses, high temperature, low battery, antenna and receiver was
                                                                                                                                                                                                                                
                                                                            
                                                                                        RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
                                                                                                USE OF SPECTRUM ANALYZER
                                                                                                            FUNDAMENTALS OF RADIO PROPAGATION AND ANTENNAS
                                                                                                                                                            UNCERTAINTIES IN MEASURING EQUIPMENT
                                                                                                                                                                        
                                                                                    
MORE INFORMATION