NARDA PMM 2260-90-80 DB
CABLES
Analog Interface Cable

NARDA PMM 2260-90-51 DB
CABLES
Serial interface cable

NARDA PMM CAVO PROBE 100 CM2 2244-90-35 DB
CABLES
Extension cable for magnetic field sensor 100-cm2
![]()  | 
GET YOUR QUOTE
MEASUREMENT AND TEST INSTRUMENTATION
ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
Campo Elettrico: No
Campo Magnetico: Sì
Campo Elettromagnetico: No
AVAILABLE
NARDA PMM
ELT-400-SET-4
2304/104
NARDA PMM ELT-400-SET-4 2304/104 DB
                                                                    
                                                                                                                                Measures Work Environments EMF
                                                                                                                                
                                                                                                                                                Environmental measures EMF LF
                                                                                                                                                
                                                                
Set the size of the magnetic field of 1 Hz - 400 kHz with: basic unit of measurement, magnetic field sensor from 100 cm <sup>2,</sup> operating manual in English, 9 Vdc power supply. Regulatory limits set: Workers ICNIRP, IEC / EN 62233 Specification for measurements on welding
                                                                        Exposure assessment than standardized ICNIRP workers and European standard EN 50366
                                                                                Operating Temperature Range: -10 ° C +50 ° C
                                                                                        Operating humidity range: <95% (30 ° C) or <29 g / m 3 without condensation
                                                                                                Weight: 910g (with probe)
                                                                                                        Typical size of the base: 180 X 100 X 55 mm
                                                                                                                Typical size of the sensor: 290 X (125 mm diameter)
                                                                                                                        Backlit LCD display
                                                                                                                                NiMH batteries (4 x AA) interchangeable
                                                                                                                                        Functionality with fully charged battery: 12 hours
                                                                                                                                                Charging time: 2 hours
                                                                                                                                                        
                                                                    
                                                                                Frequency range (-3dB), selectable 1 Hz - 400 kHz, 10 Hz - 400 kHz, 30 Hz - 400 kHz
                                                                                        Damage level sensor: 160MT (RMS) level decreases linearly with increasing frequency 77.5 Hz (1 / f)
                                                                                                Damage level sensor: 226mT (Peak) The level is reduced linearly with increasing frequency 626 Hz (1 / f)
                                                                                                        Features of the peak applied for pulses of duration <= 15.6 ms and duty cycle <= 1 / 64
                                                                                                                Typical measurement uncertainty: + / - 6% (50 Hz - 120 kHz)
                                                                                                                        Answer electric fields: <187.5 nT @ f <2 kHz, 100 V / m / <2.8 mT @ f = 50 Hz, 50 kV / m
                                                                                                                                Tripod: 1/4__
                                                                                                                                        Resolution: 0.001% (low range) with standard setting
                                                                                                                                                Range magnetic field: 80 mT (with EN 50366)
                                                                                                                                                        Resolution: 1NT (low range) with magnetic field strength approach
                                                                                                                                                                Analog output of the three channels X, Y, Z separated
                                                                                                                                                                        Interface for data reading and remote control: RS232
                                                                                                                                                                                
                                                                            
                                                                                        THEORY AND MEASURES ELF (EXTREMLY LOW FREQUENCY) AND REGULATIONS
                                                                                                UNCERTAINTIES IN MEASURING EQUIPMENT
                                                                                                                        
                                                                                    
MORE INFORMATION

Analog Interface Cable

Serial interface cable

Extension cable for magnetic field sensor 100-cm2