MPB PM-50-D PM-50 SIT
ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
Calibration of Personal Protective Equipment (PPE) with display low-frequency measures for workers and the population
![]()  | 
GET YOUR QUOTE
MEASUREMENT AND TEST INSTRUMENTATION
ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
Campo Elettrico: No
Campo Magnetico: Sì
Campo Elettromagnetico: No
AVAILABLE
MPB
PM-50-D
MPB PM-50-D PM-50 DB
                                                                    
                                                                                                                                Measures Work Environments EMF
                                                                                                                                
                                                                                                                                                Environmental measures EMF LF
                                                                                                                                                
                                                                
Personal Protective Equipment (PPE) to display low-frequency measures for workers and the population
                                                                        Frequency range 25 Hz - 30 kHz
                                                                                Allows you to monitor and protect the person from the risk of exceeding the threshold for low frequency magnetic fields through their placement on the legs, torso and waist.
                                                                                        The'individuazione s ensor of the device so that we can put in a targeted manner.
                                                                                                Through the acquisition is still possible to keep track of all the values of the magnetic field to which the 'individual undergoes during the course of its business.
                                                                                                        It is possible to set an alarm threshold and to overcome it will activate the LED lights up red warning in the vicinity of the sensors.
                                                                                                                Battery powered 2 AA Alkaline or Ni-MH 2
                                                                                                                        Rechargeable Battery life> 80h / >168h (Ni-MH 1900mA/h)
                                                                                                                                Dimensions 118 x 79 x 25 mm Weight 125 g
                                                                                                                                        Anchor Kit waist and table
                                                                                                                                                Accessories USB cable and software programming and downloading data from PC
                                                                                                                                                        
                                                                    
                                                                                Sensor type triaxial magnetoresistive
                                                                                        Frequency response @ full band: <1 dB from 38 Hz - 10 kHz, <3 dB from 25 Hz - 30 kHz
                                                                                                Measuring range 300 nT - 1 mT
                                                                                                        Resolution 10 nT
                                                                                                                Overload 2 mT
                                                                                                                        70 dB dynamic
                                                                                                                                Measurement error @ 40 - 1000 Hz - 1 - 300μT
                                                                                                                                        Linearity 1.2 dB
                                                                                                                                                Absolute error 1.6 dB
                                                                                                                                                        Measurement Units mT, A / m
                                                                                                                                                                Measurement mode selectable: selective 50Hz 50Hz + harmonics Broadband
                                                                                                                                                                        Data Logger, max recording time 168h; Acquisition time from 5...30 sec (24h); 30 sec.(168h)
                                                                                                                                                                                Display LCD 2 line x 16 character backlit
                                                                                                                                                                                        Multifunction LED: Green LED - measured, Red LED - over alarm
                                                                                                                                                                                                I / O interface: USB
                                                                                                                                                                                                        Audible alarm pre-set thresholds from 1 mT to 500 mT step 1 mT
                                                                                                                                                                                                                Auto power off: 20min; 60min; disabled
                                                                                                                                                                                                                        Date and clock: set by the operator
                                                                                                                                                                                                                                Operating temperature -10 ° - 40 ° C
                                                                                                                                                                                                                                        Reference standard Directive 2004/40/EC
                                                                                                                                                                                                                                                
                                                                            
                                                                                        THEORY AND MEASURES ELF (EXTREMLY LOW FREQUENCY) AND REGULATIONS
                                                                                                                        
                                                                                    
MORE INFORMATION

Calibration of Personal Protective Equipment (PPE) with display low-frequency measures for workers and the population