Main Category:
                                        
                                            MEASUREMENT AND TEST INSTRUMENTATION
                                        
                                        
                                        Secondary Category:
                                        
                                            ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS
                                        
                                        
                                        
                                            Specification
                                            
                                                Campo Elettrico: No
                                            
                                            
                                                Campo Magnetico: No
                                            
                                            
                                                Campo Elettromagnetico: Sì
                                            
                                            
                                            
                                                Status:
                                                
                                                    NOT AVAILABLE
                                                
                                                
                                                Brand:
                                                
                                                    NARDA PMM
                                                
                                                
                                                Model Name:
                                                
                                                    ESM 30 SLOW ICNIRP/LAVORATORI ELF IMMUNE
                                                
                                                
                                                
                                                    Part number:
                                                    
                                                        2251/76/E
                                                    
                                                    
                                                        
                                                        
                                                            Item Code:
                                                            
                                                                NARDA PMM ESM 30 SLOW ICNIRP/LAVORATORI ELF IMMUNE RADMAN XT 2251/76/E DB VND
                                                            
                                                            
                                                                
                                                                Applications:
                                                                
                                                                    
                                                                
                                                                
                                                                
                                                                Description:
                                                                
                                                                    Electromagnetic field meter staff with data logger incorporato.Immune frequency electric fields (50/60 Hz). Frequency range electric component 27 MHz - 40 GHz, the magnetic component 1 MHz - 1 GHz. Simultaneous measurement of electric and magnetic component of electromagnetic field technology, according to the Standard Shaped ICNIRP / workers
								
                                                                
                                                                
                                                                
                                                                    General Features:
                                                                    
                                                                        Audible alarm threshold to overcome useful for noisy environments
                                                                                Applications: Monitoring of RF signals in Telecommunications, Broadcast and TV and radio for leakage to RF-MW in the vicinity of coaxial cables, splices, connectors
                                                                                        LED indication 12.5%, 25%, 50% and 100% of the ICNIRP Standard / workers of equivalent power density
                                                                                                Alert threshold: 50% of the ICNIRP Standard / workers of equivalent power density ± 1 dB at a frequency equal
                                                                                                        Sensors: light emitting diode technology for electric and magnetic component
                                                                                                                Battery power supply (included) with a duration of type 2 X AAA 200 hours when the alarm off
                                                                                                                        Recommended calibration interval: 36 months
                                                                                                                                Certificate of Calibration included
                                                                                                                                        
                                                                    
                                                                    
                                                                        
                                                                        
                                                                            Specifications:
                                                                            
                                                                                Max applicable level (CW): 20 dB above the standard but not more than 10 kV / m or 26.5 A / m
                                                                                        Max applicable level (Peak): 40 dB above the standard for pulse width <10μs
                                                                                                Sensitivity: 6% of the Standard
                                                                                                        Frequency Response (flatness): Component Magnetic ± 3 dB ± 3 dB electrical component (up to 3 GHz), +4 / -3 dB (3 GHz to 10 GHz), +6 / -3 dB (10 GHz to 18 GHz), +6 / -10 dB (18 GHz to 40 GHz)
                                                                                                                Isotropic response: +4 / -2 dB (27 MHz to 500 MHz)
                                                                                                                        Immunity to electric fields Low Frequency (50/60 Hz): 100 kV / m
                                                                                                                                Recommended calibration interval: 36 months
                                                                                                                                        Operating Temperature Range: -10 ° C to +55 ° C
                                                                                                                                                Storage Temperature Range: -40 ° C to +70 ° C
                                                                                                                                                        Dimensions: 37 x 41 x 163 mm
                                                                                                                                                                Weight: 130 g
                                                                                                                                                                        Headset included
                                                                                                                                                                                
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                    Associated Courses:
                                                                                    
                                                                                        RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
                                                                                                UNCERTAINTIES IN MEASURING EQUIPMENT